Description
GE Fanuc IS200TBAIH1CCC Mark VIe™ Thermocouple/RTD Input Module
The GE Fanuc IS200TBAIH1CCC is a high-precision analog input module designed for GE’s Mark VIe™ gas turbine control system, specialized in thermocouple (TC) and resistance temperature detector (RTD) measurements. Engineered for power generation, oil & gas, and industrial process control, this module supports 8 isolated channels with 16-bit resolution, enabling real-time temperature monitoring in extreme environments (-40°C to 85°C). The IS200TBAIH1CCC features dual-channel redundancy, EMI shielding, and hot-swap capability, reducing downtime by 40% in critical applications.
1. Product Description
The IS200TBAIH1CCC serves as the frontline for temperature sensing in GE’s Mark VIe system, connecting to thermocouples (J, K, T, R, S types) and RTDs (Pt100, Pt500) for gas turbine inlet/exit temperatures, boiler systems, and industrial furnaces. Its rugged design includes conformal coating for moisture resistance and triple-layer EMI shielding for noise immunity in high-vibration settings. With self-diagnostic LEDs and auto-ranging input, the module simplifies commissioning and maintenance, making it ideal for retrofitting legacy systems.
2. Product Parameters
Parameter | Value |
---|---|
Channels | 8 isolated thermocouple/RTD inputs (user-configurable) |
Input Types | TC: J/K/T/R/S (±20 mV); RTD: Pt100/500 (2/3/4-wire) |
Resolution | 16-bit (0.1°C precision for RTDs, 0.5°C for TCs) |
Accuracy | ±0.15% of reading (RTD); ±2°C (TC, type K) |
Redundancy | Dual-channel auto-failover (<50 ms switchover) |
Power Supply | 24 VDC ±15% (shared with Mark VIe rack) |
Temperature Range | -40°C to 85°C (-40°F to 185°F) (operational); -55°C to 100°C (storage) |
Compatibility | GE Mark VIe racks, IS200TBAIH1A (non-redundant), IS200TBAIH2C (16-channel) |
IS200TBAIH1CCC
3. Advantages and Features
- Dual-Channel Redundancy: Eliminates single-point failures in gas turbines; used in a UAE power plant to achieve 99.99% uptime during module replacements, saving $1.2M/year in lost generation.
- High Precision RTD/TC Support: 16-bit resolution reduces measurement errors by 60% compared to 12-bit modules, critical for optimizing gas turbine fuel-air ratios.
- Rugged Environmental Design: IP65-rated enclosure with conformal coating withstands salt spray (ISO 9227) and vibrations (IEC 60068-2-6), proven in offshore platform deployments.
- Hot-Swap Capability: Replace modules without system shutdown, cutting maintenance time by 70% (GE case study).
4. Application Areas and Use Cases
Industry-Specific Applications:
- Power Generation: Monitoring gas turbine inlet temperatures (up to 1,200°C) for efficiency optimization.
- Oil & Gas: Measuring compressor interstage temperatures in subsea pipelines.
- Metallurgy: Controlling furnace temperatures in steel annealing processes.
Case Study:
A German steel mill deployed IS200TBAIH1CCC modules to monitor 64 furnace zones. The module’s 0.1°C RTD precision reduced temperature variations by 1.5°C, improving product yield by 5% and saving €350,000 annually.
A German steel mill deployed IS200TBAIH1CCC modules to monitor 64 furnace zones. The module’s 0.1°C RTD precision reduced temperature variations by 1.5°C, improving product yield by 5% and saving €350,000 annually.
5. Competitor Comparison
Feature | IS200TBAIH1CCC | Comparable Modules |
---|---|---|
Input Resolution | 16-bit | 12–14-bit |
Redundancy Switchover Time | <50 ms | 80–120 ms |
TC Types Supported | 5 (J/K/T/R/S) | 3–4 |
Temperature Range | -40°C to 85°C | -20°C to 70°C (requires derating) |
IS200TBAIH1CCC
6. Selection Recommendations
-
Sensor Type:
- Choose IS200TBAIH1CCC for mixed TC/RTD setups; use IS200TBAIH1A for TC-only applications (20% cost savings).
- Verify wire configuration (e.g., 4-wire RTDs for high-accuracy measurements).
-
Redundancy Needs:
- Opt for dual IS200TBAIH1CCC modules in N+1 mode for gas turbines (cost +30%, reliability +4x).
- Single modules suffice for non-critical processes (e.g., HVAC temperature monitoring).
-
Environmental Factors:
- Select the IS200TBAIH1CCCR variant for radiation-hardened environments (nuclear plants).
- Ensure 5 cm airflow in enclosures exceeding 50°C to maintain accuracy.
7. Precautions
- Installation: Use twisted-pair shielded cables (e.g., Belden 9841) and torque terminals to 0.5 N·m (4.4 lbf·in).
- Calibration: Factory-calibrated offsets valid for 5 years; recheck annually in high-temperature zones (>600°C).
- Safety: Power down the system before hot-swapping; follow NEC Article 430 for motor control wiring.