Sale!

IS200TBCIH1BBC GE

  • Dual-Channel Redundancy: A Middle Eastern power plant achieved 99.99% uptime during module swaps, avoiding $1.8M/year in lost generation.
  • High Precision: 16-bit resolution reduces RTD measurement errors by 60% vs. 12-bit modules, critical for optimizing gas turbine fuel-air ratios.
  • Rugged Design: IP65-rated enclosure with conformal coating withstands salt spray (ISO 9227) and 5 g vibrations (IEC 60068-2-6), proven in 10+ years of offshore deployments.
  • Hot-Swap Capability: 70% faster maintenance than legacy modules (GE case study: 15-minute vs. 50-minute replacement).
In Stock
Manufacturer:
Part number: IS200TBCIH1BBC
Our extensive catalogue, including : IS200TBCIH1BBC , is available now for dispatch to the worldwide.

Description

GE Fanuc IS200TBCIH1BBC Mark VIe™ Thermocouple/RTD Input Module

 

The GE Fanuc IS200TBCIH1BBC is a high-precision analog input module designed for GE’s Mark VIe™ gas turbine control system, specializing in thermocouple (TC) and resistance temperature detector (RTD) measurements. Engineered for power generation, oil & gas, and industrial process control, this module supports 8 isolated channels with 16-bit resolution, enabling real-time temperature monitoring in extreme environments (-40°C to 85°C). The IS200TBCIH1BBC features dual-channel redundancy, EMI shielding, and hot-swap capability, reducing unplanned downtime by 45% in critical applications like gas turbines and boilers.

1. Product Description

The IS200TBCIH1BBC serves as the primary interface for temperature sensing in GE’s Mark VIe system, connecting to thermocouples (J/K/T/R/S types) and RTDs (Pt100/Pt500). Its rugged design includes conformal coating for moisture resistance and triple-layer EMI shielding, ensuring stable performance in high-vibration settings (e.g., offshore platforms, steel mills). With auto-ranging inputs and self-diagnostic LEDs, the module simplifies commissioning and maintenance, while dual-channel redundancy (N+1) eliminates single points of failure. Key applications include gas turbine inlet temperature control, boiler efficiency optimization, and industrial furnace monitoring.

2. Product Parameters

Parameter Value
Channels 8 isolated TC/RTD inputs (configurable per channel)
Input Types TC: J/K/T/R/S (±20 mV); RTD: Pt100/500 (2/3/4-wire)
Resolution 16-bit (0.1°C for RTDs, 0.5°C for TCs)
Accuracy ±0.15% (RTD); ±2°C (TC, type K)
Redundancy Dual-channel auto-failover (<50 ms switchover)
Power Supply 24 VDC ±15% (rack-powered)
Temperature Range -40°C to 85°C (operational); -55°C to 100°C (storage)
Compatibility GE Mark VIe racks, IS200TBCIH1A (non-redundant), IS200TBCIH2C (16-channel)
IS200TBCIH1BBC

IS200TBCIH1BBC

3. Advantages and Features

  • Dual-Channel Redundancy: A Middle Eastern power plant achieved 99.99% uptime during module swaps, avoiding $1.8M/year in lost generation.
  • High Precision: 16-bit resolution reduces RTD measurement errors by 60% vs. 12-bit modules, critical for optimizing gas turbine fuel-air ratios.
  • Rugged Design: IP65-rated enclosure with conformal coating withstands salt spray (ISO 9227) and 5 g vibrations (IEC 60068-2-6), proven in 10+ years of offshore deployments.
  • Hot-Swap Capability: 70% faster maintenance than legacy modules (GE case study: 15-minute vs. 50-minute replacement).

4. Application Areas and Use Cases

Industry-Specific Applications:
  • Power Generation: Monitoring gas turbine inlet temperatures (1,200°C max) for efficiency optimization.
  • Oil & Gas: Measuring subsea pipeline compressor temperatures to prevent icing (BP 案例:提前 3 days 预警,避免 $2.5M repair).
  • Metallurgy: Controlling annealing furnace temperatures in steel production (某宝钢案例:温度波动≤1°C,良品率提升 4%).
Case Study:
A German biomass power plant deployed IS200TBCIH1BBC to monitor 32 boiler zones. The module’s RTD precision reduced fuel consumption by 6%, saving €400,000 annually while extending boiler 寿命 by 2 years.

5. Competitor Comparison

Feature IS200TBCIH1BBC Comparable Modules
Redundancy Switchover Time <50 ms 80–120 ms
TC Types Supported 5 (J/K/T/R/S) 3–4
RTD Wire Support 4-wire (factory-calibrated) 2/3-wire (field-calibration required)
MTBF 180,000 hours 120,000 hours
IS200TBCIH1BBC

IS200TBCIH1BBC

6. Selection Recommendations

  1. Sensor Type:
    • Choose IS200TBCIH1BBC for mixed TC/RTD setups; use IS200TBCIH1A for TC-only (25% cost savings).
    • 4-wire RTDs recommended for <0.1°C accuracy (e.g., turbine inlet sensors).
  2. Redundancy Needs:
    • Dual modules (N+1) for gas turbines and offshore assets (cost +35%, failure risk ↓80%).
    • Single modules for non-critical processes (e.g., HVAC, water pumps).
  3. Environmental Factors:
    • IS200TBCIH1BBCH variant for -55°C to 125°C (Arctic LNG plants).
    • Ensure 5 cm airflow in enclosures >50°C to maintain accuracy.

7. Precautions

  • Installation: Use shielded twisted-pair cables (Belden 9841) and torque terminals to 0.5 N·m.
  • Calibration: Factory offsets valid for 5 years; recheck annually in high-temperature zones (>600°C).
  • Safety: Power down before hot-swapping; follow NEC 501 for hazardous locations (Class I, Div 2).
Shanxi Runsheng Import and Export Co., LTD. Our main products: FOXBORO, EMERSON, TRICONEX, XYCOM, BENTLY, ROCKWELL, ABB, GE, Allen-Bradley, YOKOGAWA, HONEYWELL, RELIANCE, SCHNEIDER, MODICON, Westin ghouse, WOODWARD, Motorola, Rexroth, SEW, Denkon. And other major brands of DCS, PLC, robot, large servo four system spare parts. Other automation spare parts sales and technical support. Please visit our website www.rsmodules.com or contact us at +86 15383514022 and we will be happy to serve you.