Sale!

IS215VPROH1BD GE

  • Dual Redundancy: Independent emergency protection system separate from the main control system, reducing single points of failure.
  • Contact Isolation: 24 isolated dry contact inputs prevent signal interference and protect against voltage spikes.
  • Hot-Swap Capability: Modular design allows maintenance without system shutdown, minimizing downtime.
  • Harsh Environment Resilience: Industrial-grade components (polyester capacitors, carbon composite resistors) ensure operation in extreme temperatures (0°C to +55°C) and high-vibration settings.
  • Testability: Manual and software-initiated trip solenoid tests validate system readiness (e.g., quarterly safety checks in power plants).
In Stock
Manufacturer:
Part number: IS215VPROH1BD
Our extensive catalogue, including : IS215VPROH1BD , is available now for dispatch to the worldwide. Brand:

Description

1. Product Description

The IS215VPROH1BD serves as an emergency turbine protection module with dual functions: contact input isolation and independent overspeed protection. It supports 24 dry contact inputs with group isolation via a TBCI terminal block, protecting the control system from external interference. The module integrates two stacked circuit boards (IS200VPRW top board and base board) with built-in safety features, including thermocouple/analog input support and trip solenoid control via the TREG board. Its compact design (2.1 × 18.8 × 26.2 cm, 0.3 kg) and DIN-rail mounting enable easy integration into Mark VI systems. Key features include LED indicators, Ethernet connectivity, and compliance with industrial standards for harsh environments.

2. Product Parameters

Parameter Specification
Brand GE Fanuc
Series Mark VI (Speedtronic Turbine Control)
Type Emergency Protection & Communication Module
Input Signals 24 dry contacts (group-isolated)
Compatibility GE Mark VI systems, TREG/TCI boards
Dimensions 2.1 cm (W) × 18.8 cm (H) × 26.2 cm (D)
Weight 0.3 kg (0.66 lbs)
Power Supply 24VDC (via TREG board)
Protection Functions Emergency overspeed, sync check, trip solenoid control
Communication Ethernet (via faceplate connectors)
Mounting DIN rail (integrated with Mark VI chassis)
IS215VPROH1BD

IS215VPROH1BD

3. Advantages and Features

  • Dual Redundancy: Independent emergency protection system separate from the main control system, reducing single points of failure.
  • Contact Isolation: 24 isolated dry contact inputs prevent signal interference and protect against voltage spikes.
  • Hot-Swap Capability: Modular design allows maintenance without system shutdown, minimizing downtime.
  • Harsh Environment Resilience: Industrial-grade components (polyester capacitors, carbon composite resistors) ensure operation in extreme temperatures (0°C to +55°C) and high-vibration settings.
  • Testability: Manual and software-initiated trip solenoid tests validate system readiness (e.g., quarterly safety checks in power plants).

4. Application Areas and Use Cases

  • Industry: Power generation (gas/steam turbines), oil & gas (pump stations), manufacturing (rotating machinery).
  • Case Study: A European power plant deployed IS215VPROH1BD in a dual-module configuration for its 500MW gas turbine. The module’s redundant overspeed protection detected a 110% speed deviation during a grid fault, triggering a safe shutdown within 50ms—preventing catastrophic damage and reducing repair costs by $2M.

5. Competitive Comparison

Compared to standard turbine protection modules:
  • Isolation Depth: 24-group isolation (vs. 12–16 groups in most alternatives).
  • Redundancy Architecture: True independent protection circuit (vs. shared logic in legacy systems).
  • Integration Flexibility: Native Mark VI compatibility (no adapters required vs. third-party modules).
  • Safety Compliance: Meets ISO 13709 (turbine control) and IEC 61508 (SIL 2) standards for critical applications.
    IS215VPROH1BD

    IS215VPROH1BD

6. Selection Recommendations

  • System Type: Use with GE Mark VI turbines (e.g., Frame 6/7) requiring emergency overspeed protection.
  • Redundancy Needs: Pair with a second IS215VPROH1BD for N+1 redundancy in high-risk installations (e.g., offshore platforms).
  • Environment: Ensure adequate ventilation; derate performance in >50°C environments.
  • Expansion: Combine with TREG/TCI boards for full turbine trip system integration.

7. Precautions

  • Installation:
    • Follow ESD protocols; use anti-static gloves.
    • Secure terminal block connections (torque: 0.5–0.7 N·m) to prevent loose contacts.
  • Maintenance:
    • Inspect capacitors for swelling every 3 years (expected lifespan: 10 years).
    • Verify trip solenoid response time (<100ms) during annual system tests.
  • Safety:
    • Disconnect power before replacing modules (24VDC isolation required).
    • Do not expose to water or conductive dust; IP20-rated (indoor use only).
Shanxi Runsheng Import and Export Co., LTD. Our main products: FOXBORO, EMERSON, TRICONEX, XYCOM, BENTLY, ROCKWELL, ABB, GE, Allen-Bradley, YOKOGAWA, HONEYWELL, RELIANCE, SCHNEIDER, MODICON, Westin ghouse, WOODWARD, Motorola, Rexroth, SEW, Denkon. And other major brands of DCS, PLC, robot, large servo four system spare parts. Other automation spare parts sales and technical support. Please visit our website www.rsmodules.com or contact us at +86 15383514022 and we will be happy to serve you.