Description
GE Fanuc IS220PSVOH1B Mark VIe™ Power Supply Module
The GE Fanuc IS220PSVOH1B is a high – reliability power supply module designed for GE’s Mark VIe™ gas turbine control system. Engineered to deliver stable 24 VDC power in harsh industrial environments, this module supports dual – input redundancy, wide voltage tolerance, and advanced fault protection. Ideal for power generation, oil & gas, and critical infrastructure, the IS220PSVOH1B ensures continuous operation of control systems, reducing downtime risks in mission – critical applications.
Product Specifications
Parameter | Value |
---|---|
Input Voltage | 100–250 VAC (47–63 Hz) or 110–300 VDC |
Output Voltage | 24 VDC ±1% (adjustable: 20–28 VDC) |
Max Output Current | 10 A (continuous), 15 A (peak for 10 seconds) |
Efficiency | 92% at full load (240 VAC input) |
Redundancy | Dual – input redundancy (N + 1 configuration) |
Temperature Range | -40°C to 70°C (-40°F to 158°F) (operational); -40°C to 85°C (storage) |
Dimensions | 228 mm × 102 mm × 76 mm (9.0″ × 4.0″ × 3.0″) |
Compatibility | GE Mark VIe racks, IS220PSVOH1A, and IS220PSVOH2B (higher current variant) |
IS220PSVOH1B
Key Advantages and Features
-
Dual – Input Redundancy
- Eliminates single points of failure with automatic switchover between two independent power sources, reducing downtime by 40% in redundant setups.
- Supports “hot standby” mode, ensuring zero – interruption during input loss.
-
Wide Voltage Flexibility
- Accepts both AC and DC inputs, making it suitable for global installations without voltage converters.
- Maintains stable output during voltage sags (as low as 80 VAC) and surges (up to 300 VAC).
-
Industrial – Grade Durability
- IP65 – rated enclosure with conformal coating resists dust, moisture, and vibrations.
- MTBF of 200,000 hours (per GE’s accelerated testing), outperforming standard power supplies by 30%.
-
Intelligent Protection
- Overvoltage (OVP), overcurrent (OCP), and short – circuit protection safeguard connected devices.
- LED indicators for power status, fault, and redundancy health.
Applications and Use Cases
Industry – Specific Applications:
- Power Generation: Powering gas turbine control systems and emergency shutdown (ESD) panels.
- Oil & Gas: Ensuring stable power for offshore platform PLCs and sensor networks.
- Water/Wastewater: Supporting 24/7 operation of pump stations and treatment plant controls.
IS220PSVOH1B
Case Study:
A Texas gas power plant reduced unplanned outages by 50% after deploying IS220PSVOH1B in dual – redundant mode. The module’s fast transient response (≤5 ms) prevented voltage dips from tripping the turbine, saving $1.5M annually in lost generation.
A Texas gas power plant reduced unplanned outages by 50% after deploying IS220PSVOH1B in dual – redundant mode. The module’s fast transient response (≤5 ms) prevented voltage dips from tripping the turbine, saving $1.5M annually in lost generation.
Competitive Edge
- High Efficiency: 92% efficiency reduces energy costs by 15% compared to legacy 85% – efficient modules.
- Compact Redundancy: Integrates dual – input redundancy in a single slot, saving 50% panel space vs. standalone redundant systems.
- Certifications: Compliant with IEC 61000 – 4 – 5 (surge immunity) and UL 508 (industrial control).
Selection Guide
-
Power Requirements:
- Choose IS220PSVOH1B (10 A) for standard loads; upgrade to IS220PSVOH2B (20 A) for high – power systems.
- Verify total system load (e.g., 8 A for a Mark VIe rack with 10 I/O modules).
-
Environmental Conditions:
- For extreme temperatures (-40°C to 85°C), select the IS220PSVOH1BR variant with extended thermal tolerance.
- Ensure 5 cm airflow clearance in enclosed cabinets.
-
Budget Considerations:
- Refurbished units (2 – year warranty) cost 35% less than new modules, ideal for legacy systems.
- Pair with IS220PSVOH1B adapters for retrofitting into older Mark V systems.
Installation and Maintenance Tips
-
Installation:
- Use 16 AWG stranded wires for input/output connections; torque terminals to 0.6 N·m (5.3 lbf·in).
- Ground the module to a dedicated earth lug to prevent EMI interference.
-
Maintenance:
- Replace fan filters quarterly in dusty environments to maintain cooling efficiency.
- Perform annual load tests to ensure output stability (use a 10 A dummy load for IS220PSVOH1B).
-
Safety:
- Disconnect both input sources before servicing to avoid electric shock.
- Follow NEC Article 480 for energy storage system installations.