Sale!

SAI143-H63 YOKOGAWA

  • High Precision: ±16 μA accuracy (0.05–23 mA) for critical process measurements.
  • HART Communication: Enables remote configuration and diagnostics of smart transmitters.
  • Module-Level Isolation: 1.5 kV AC protection against ground loops and interference.
  • Dual-Redundancy Support: Compatible with ProSafe-RS redundant systems for fault tolerance.
  • Wide Environmental Range: Operates in -20°C to 70°C (ISA G3 compliance for corrosive environments).
  • Flexible Wiring: Supports pressure clamp terminals, MIL cables, or dedicated signal adapters.
In Stock
Manufacturer:
Part number: SAI143-H63
Our extensive catalogue, including : SAI143-H63 , is available now for dispatch to the worldwide. Brand:

Description

1. Product Description

The YOKOGAWA SAI143-H63 is a 16-channel analog input module designed for Yokogawa’s ProSafe-RS Safety Instrumented System (SIS), offering high precision and reliability for critical industrial applications. Engineered for 4–20 mA signals (with a permissible range of 0–25 mA), the SAI143-H63 supports HART communication and features module-level isolation to protect against electrical interference. Its compact design (115 mm × 22.5 mm × 90 mm) and DIN rail mounting enable easy integration into safety-critical systems in industries such as oil and gas, chemical processing, and power generation. With a wide operating temperature range (-20°C to 70°C) and ISA G3 compliance, the module withstands harsh environments while delivering ±16 μA accuracy (0.05–23 mA input range).

2. Technical Parameters

Parameter Specification
Type Analog input module (ProSafe-RS SIS)
Channels 16 (module-isolated)
Input Range 4–20 mA (permissible: 0–25 mA)
Accuracy ±16 μA (0.05–23 mA)
Input Impedance 250 Ω (power-on), 500 kΩ minimum (power-off)
Data Update Frequency 40 ms
Transmitter Power Supply 16.15–26.4 V DC (25 mA current limit)
Withstand Voltage 1.5 kV AC (input signal to system, 1 minute)
Power Consumption 5V: 320 mA; 24V: 550 mA
Operating Temperature -20°C to 70°C (storage: -40°C to 85°C)
Humidity 5–95% RH (non-condensing)
Weight 0.34–0.39 kg (depending on terminal type)
Compatibility Yokogawa ProSafe-RS SIS
SAI143-H63

SAI143-H63

3. Advantages and Features

  • High Precision: ±16 μA accuracy (0.05–23 mA) for critical process measurements.
  • HART Communication: Enables remote configuration and diagnostics of smart transmitters.
  • Module-Level Isolation: 1.5 kV AC protection against ground loops and interference.
  • Dual-Redundancy Support: Compatible with ProSafe-RS redundant systems for fault tolerance.
  • Wide Environmental Range: Operates in -20°C to 70°C (ISA G3 compliance for corrosive environments).
  • Flexible Wiring: Supports pressure clamp terminals, MIL cables, or dedicated signal adapters.

4. Application Areas and Cases

  • Industry Applications: Oil and gas, chemical processing, power generation, pharmaceuticals.
  • Use Cases:
    • Refinery Safety Systems: Monitors pressure/temperature transmitters in a distillation unit, with HART-enabled diagnostics reducing downtime by 30% (case study: 2024 refinery upgrade project).
    • Chemical Reactor Control: 16-channel isolation ensures safe signal monitoring in a polymerization process, meeting IEC 61508 SIL 3 requirements.

5. Competitor Comparison

Compared to similar analog input modules:

 

  • Higher Channel Density: 16 channels (vs. 8–12 channels in most 竞品), reducing panel space by 30%.
  • Enhanced Safety Compliance: Certified for ProSafe-RS SIS (SIL 3 capable), surpassing basic industrial modules.
  • Extended Temperature Range: Operates at -20°C to 70°C (vs. typical 0°C to 50°C in 竞品), suitable for outdoor/extreme environments.
    SAI143-H63

    SAI143-H63

6. Selection Recommendations

  • System Compatibility: Verify ProSafe-RS SIS firmware (≥R1.02.00) and module redundancy needs.
  • Environment: Choose -H63 suffix for ISA G3 corrosion resistance (vs. standard models).
  • Signal Type: Use 2/4-wire configuration via channel pins (2-wire with transmitter power supply control).
  • Budget: Balance channel density (16 channels) with project scale (cost-effective for SIL-rated systems).

7. Precautions

  • Installation: Secure DIN rail mounting; avoid liquid exposure (IP20 protection).
  • Wiring: Use shielded cables for HART signals; maintain 24V DC stability (±10% tolerance).
  • Maintenance: Regularly update HART device configurations; replace every 7–10 years (Yokogawa guidelines).
  • Safety: Follow IEC 61508 for SIL-rated applications; disconnect power before servicing.
Shanxi Runsheng Import and Export Co., LTD. Our main products: FOXBORO, EMERSON, TRICONEX, XYCOM, BENTLY, ROCKWELL, ABB, GE, Allen-Bradley, YOKOGAWA, HONEYWELL, RELIANCE, SCHNEIDER, MODICON, Westin ghouse, WOODWARD, Motorola, Rexroth, SEW, Denkon. And other major brands of DCS, PLC, robot, large servo four system spare parts. Other automation spare parts sales and technical support. Please visit our website www.rsmodules.com or contact us at +86 15383514022 and we will be happy to serve you.