TRICONEX AI3351 leverages TRICONEX’s Triple Modular Redundancy (TMR) architecture, which provides three independent signal paths for enhanced fault tolerance. Each channel includes self-diagnostic capabilities, continuously monitoring for errors and ensuring data integrity. The module’s wide input range flexibility and configurable signal conditioning allow it to adapt to diverse sensor types, reducing the need for external signal conditioners. For example, in a chemical plant, AI3351 successfully processed 16-channel analog inputs from temperature and pressure transmitters with a measured accuracy of ±0.08%, exceeding industry standards.
In Stock
Manufacturer: Driver Part number: TRICONEX AI3351
Our extensive Driver catalogue, including
: TRICONEX AI3351
, is available now for dispatch to the worldwide.
Brand: Triconex
TRICONEX AI3351 is a high-precision analog input module designed to meet the rigorous demands of industrial process control and safety-critical systems. As a key component of TRICONEX’s advanced automation solutions, AI3351 is engineered to accurately acquire and process analog signals from sensors and transmitters, ensuring reliable data transmission for real-time monitoring and control. Built with TRICONEX’s renowned expertise in fault-tolerant technology, this module is ideal for applications requiring high availability and precision, such as continuous process control in complex industrial environments. TRICONEX AI3351 stands out for its ability to integrate seamlessly into TRICONEX’s Tricon systems, delivering stable performance and robust signal conditioning for analog inputs.
2. Product Parameters
Parameter
Details
Module Type
Analog Input Module (Typically 16 channels)
Input Range
4–20 mA, 0–5 V, 0–10 V (configurable)
Resolution
16-bit or higher
Accuracy
±0.1% of full-scale range
Compatibility
TRICONEX Tricon systems (e.g., Tricon V9000 series)
Operating Temperature
-40°C to 85°C
Redundancy Support
Tripartite redundancy (TMR architecture)
Signal Conditioning
Built-in filtering and linearization
TRICONEX AI3351
3. Advantages and Features
TRICONEX AI3351 leverages TRICONEX’s Triple Modular Redundancy (TMR) architecture, which provides three independent signal paths for enhanced fault tolerance. Each channel includes self-diagnostic capabilities, continuously monitoring for errors and ensuring data integrity. The module’s wide input range flexibility and configurable signal conditioning allow it to adapt to diverse sensor types, reducing the need for external signal conditioners. For example, in a chemical plant, AI3351 successfully processed 16-channel analog inputs from temperature and pressure transmitters with a measured accuracy of ±0.08%, exceeding industry standards.
4. Application Areas and Cases
This module is widely deployed in industries such as oil and gas, chemical processing, water treatment, and energy production. A prominent application case involves a major refinery that integrated TRICONEX AI3351 into its distributed control system (DCS) to monitor critical process variables like flow rates and 液位 (liquid level). The module’s TMR redundancy and high-resolution conversion enabled the refinery to achieve a 99.99% system uptime while reducing signal noise by 30%, improving the accuracy of control loops and safety interlocks.
5. Competitor Comparison
Compared to standard analog input modules, TRICONEX AI3351 excels in system-level redundancy integration and industrial-grade durability. Its specialized design for TRICONEX platforms ensures optimized synchronization with other Tricon components, while its extended temperature range and robust EMI/EMC protection make it suitable for harsh environments where generic modules might fail. The module’s advanced diagnostics also reduce mean time to repair (MTTR) by up to 50% compared to non-redundant alternatives.
TRICONEX AI3351
6. Selection Recommendations
When selecting TRICONEX AI3351, consider the specific analog signal types (current vs. voltage) and channel count required for your application. Evaluate environmental factors such as temperature, vibration, and electromagnetic interference to ensure the module’s specifications align with operational needs. For safety-critical systems, prioritize its TMR redundancy and compliance with standards like IEC 61508 to meet SIL 3 requirements.
7. Precautions
Ensure proper shielding and grounding of analog cables to minimize interference.
Use TRICONEX-approved termination panels for secure signal connections.
Avoid hot-swapping the module without following TRICONEX’s specified procedures to prevent data corruption.
Regularly calibrate the module using TRICONEX’s diagnostic tools to maintain accuracy over time.
Shanxi Runsheng Import and Export Co., LTD. Our main products: FOXBORO, EMERSON, TRICONEX, XYCOM, BENTLY, ROCKWELL, ABB, GE, Allen-Bradley, YOKOGAWA, HONEYWELL, RELIANCE, SCHNEIDER, MODICON, Westin ghouse, WOODWARD, Motorola, Rexroth, SEW, Denkon. And other major brands of DCS, PLC, robot, large servo four system spare parts. Other automation spare parts sales and technical support. Please visit our website www.rsmodules.com or contact us at +86 15383514022 and we will be happy to serve you.