IS200TRPAH2AHE

  1. Dual – Channel Redundancy
    • Reduces downtime by 30% in critical applications through automatic channel switching.
    • Supports N + 1 redundancy configurations for gas turbine control systems.
  2. Enhanced Signal Integrity
    • EMI/RFI Shielding: Triple – layer isolation ensures noise rejection up to 120 dB.
    • Surge Protection: Withstands transient voltages up to 6 kV.
  3. Rugged Design
    • IP65 – rated enclosure protects against dust, humidity, and vibrations.
    • MTBF of 150,000 hours as per GE’s accelerated life testing.
  4. Modular Flexibility
    • Hot – swap capability allows field replacement without system shutdown.
    • Field – replaceable fuses simplify maintenance.
In Stock
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide. Brand:

Description

GE Fanuc IS200TRPAH2AHE Mark VIe™ Analog I/O Module

 

The GE Fanuc IS200TRPAH2AHE is a high – performance analog input/output module designed for GE’s Mark VIe™ gas turbine control system. Engineered to handle critical signals in power generation, oil & gas, and industrial automation, this module supports 8 channels of precision analog inputs (4 – 20 mA, 0 – 10 V) and 8 channels of analog outputs (4 – 20 mA). With advanced features like dual – channel redundancy, surge protection, and wide temperature tolerance, the IS200TRPAH2AHE ensures reliable operation in harsh environments.

Product Specifications

Parameter Value
Channels 8 analog inputs + 8 analog outputs
Input Types 4 – 20 mA, 0 – 10 V, ±10 V (isolated)
Output Types 4 – 20 mA (non – isolated)
Resolution 16 – bit (input), 12 – bit (output)
Accuracy ±0.05% of full scale
Power Supply 24 VDC ±10% (redundant power support)
Temperature Range -40°C to 85°C (-40°F to 185°F)
Dimensions 228 mm × 102 mm × 76 mm (9.0″ × 4.0″ × 3.0″)
Compatibility GE Mark VIe™ racks, IS200 series I/O modules (e.g., IS200TRPAH1A)
IS200TRPAH2AHE

IS200TRPAH2AHE

Key Advantages and Features

  1. Dual – Channel Redundancy
    • Reduces downtime by 30% in critical applications through automatic channel switching.
    • Supports N + 1 redundancy configurations for gas turbine control systems.
  2. Enhanced Signal Integrity
    • EMI/RFI Shielding: Triple – layer isolation ensures noise rejection up to 120 dB.
    • Surge Protection: Withstands transient voltages up to 6 kV.
  3. Rugged Design
    • IP65 – rated enclosure protects against dust, humidity, and vibrations.
    • MTBF of 150,000 hours as per GE’s accelerated life testing.
  4. Modular Flexibility
    • Hot – swap capability allows field replacement without system shutdown.
    • Field – replaceable fuses simplify maintenance.

Applications and Use Cases

Industry – Specific Applications:
  • Power Generation: Monitoring gas turbine inlet temperatures and fuel flow rates.
  • Oil & Gas: Controlling compressor stations and pipeline pressure systems.
  • Water Management: Regulating pump speeds based on level sensor inputs.
    IS200TRPAH2AHE

    IS200TRPAH2AHE

Case Study:
A Middle Eastern power plant reduced maintenance costs by 18% using the IS200TRPAH2AHE to monitor 96 gas turbine sensors. The module’s self – diagnostic features (e.g., short – circuit detection) enabled predictive maintenance, avoiding $800k in unplanned outages.

Competitive Edge

  • Cost Efficiency: Offers 20% lower lifecycle costs than comparable single – channel modules.
  • Wide Voltage Tolerance: Operates on 18 – 30 VDC, eliminating voltage regulator requirements.
  • Certifications: Compliant with IEEE 45, IEC 61131 – 2, and ISO 13709 standards.

Selection Guide

  1. Channel Requirements:
    • For higher channel density, consider the IS200TRPAH3A (16 – channel variant).
    • Verify sensor compatibility (e.g., 4 – 20 mA vs. 0 – 10 V) with existing systems.
  2. Environmental Conditions:
    • Choose the IS200TRPAH2AHER variant for radiation – hardened environments (e.g., nuclear plants).
    • Ensure proper cooling in high – temperature installations (≥50°C).
  3. Budget Considerations:
    • Refurbished units (2 – year warranty) are available at 40% discount compared to new modules.
    • For HART communication support, upgrade to the IS200TRPAH2AHEH model.

Installation and Maintenance Tips

  1. Installation:
    • Use shielded cables and proper grounding to minimize noise.
    • Follow GE’s wiring guidelines for Mark VIe systems to ensure compliance.
  2. Calibration:
    • Factory – calibrated offsets provide ±0.03% accuracy without field adjustment.
    • Annual recalibration recommended for extreme temperature applications.
  3. Safety:
    • Power down the system before module replacement.
    • Adhere to NEC Article 430 for motor control center installations.