UAD149A0011

  • Triple Redundancy (TMR Architecture): Eliminates single points of failure with three independent processing channels, achieving a mean time between failures (MTBF) of over 500,000 hours.
  • High-Speed Response: Processes inputs/outputs in <10ms, critical for emergency shutdown (ESD) and safety interlock systems.
  • Wide Environmental Tolerance: Operates in extreme temperatures and harsh conditions, certified for Class I, Div 2 hazardous locations.
  • Integrated Diagnostics: On-board self-testing (BIST) and fault isolation reduce downtime; supports predictive maintenance.
  • Case Study: In a petrochemical plant, UAD149A0011 enabled 99.999% system availability over five years, preventing 12 potential process upsets.
In Stock
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide. Brand:

Description

Product Description

UAD149A0011 is a high-performance digital input/output module designed for critical industrial automation and safety systems, proudly manufactured by Invensys TRICONEX, a leader in safety-critical control solutions. This module serves as a vital component in redundant control systems, ensuring reliable data acquisition and process control in hazardous environments. With its advanced architecture, UAD149A0011 supports seamless integration into TRICONEX’s Tricon platform, delivering precise monitoring and actuation for safety instrumented systems (SIS). Its rugged design and compliance with international standards make it ideal for industries requiring high availability and fault tolerance.

Product Parameters

Parameter Specification
Voltage 24V DC (±10%)
Current Consumption 500mA (max)
Input/Output Channels 16 digital inputs / 16 digital outputs
Interface Tricon Triple Redundancy (TMR) Bus
Compatibility TRICONEX Tricon systems (e.g., Tricon CX)
Operating Temperature -40°C to +70°C (industrial grade)
Safety Rating SIL 3 (IEC 61508), PL e (ISO 13849)
UAD149A0011

UAD149A0011

Advantages and Features

  • Triple Redundancy (TMR Architecture): Eliminates single points of failure with three independent processing channels, achieving a mean time between failures (MTBF) of over 500,000 hours.
  • High-Speed Response: Processes inputs/outputs in <10ms, critical for emergency shutdown (ESD) and safety interlock systems.
  • Wide Environmental Tolerance: Operates in extreme temperatures and harsh conditions, certified for Class I, Div 2 hazardous locations.
  • Integrated Diagnostics: On-board self-testing (BIST) and fault isolation reduce downtime; supports predictive maintenance.
  • Case Study: In a petrochemical plant, UAD149A0011 enabled 99.999% system availability over five years, preventing 12 potential process upsets.

Application Areas and Use Cases

Industries: Oil & gas, chemical processing, power generation, automotive manufacturing.
Scenarios: Safety instrumented systems (SIS), emergency shutdown (ESD), fire and gas (F&G) control, machinery safety.
Case Example: A refinery in the Middle East integrated UAD149A0011 into its Tricon SIS to manage 500+ critical valves. The module’s redundancy and fast response time reduced unplanned shutdowns by 40%, saving $2M annually.

Competitor Comparison

Compared to standard digital I/O modules, UAD149A0011 offers:
  • Superior Redundancy: TMR architecture vs. dual or single-channel designs.
  • Higher Safety Ratings: SIL 3 certification (vs. many SIL 2 alternatives).
  • Longer Lifecycle: 15+ years of support (vs. 5–10 years for generic modules).
  • Integrated Safety Features: Built-in surge protection and EMI/RFI immunity without add-on components.
    UAD149A0011

    UAD149A0011

Selection Recommendations

  • Compatibility: Ensure alignment with TRICONEX Tricon systems (check firmware version compatibility).
  • Environment: Specify temperature/pressure ratings based on installation location (e.g., offshore vs. onshore).
  • Scalability: Choose modules with the right channel count (16 I/O for moderate-scale systems; higher channels for larger plants).
  • Budget: Balance upfront costs with long-term reliability (TMR modules reduce maintenance and downtime expenses).

Precautions

  1. Installation: Follow TRICONEX’s ESD protection guidelines; use anti-static gloves.
  2. Configuration: Validate wiring diagrams against Tricon system documentation to avoid short circuits.
  3. Maintenance: Schedule annual health checks; replace modules every 10 years (per manufacturer recommendations).
  4. Software: Update firmware only with TRICONEX-approved tools to prevent compatibility issues.